Convection: 0.2 kW (0.25 HP) drive ratings, Catalog Numbers 22A-V1P5N104, 22A-A1P5N114, 22A-A1P5104 and 22A-B1P5N104
-
Fan: All other drive ratings.
-
Storage Temperature: 40 to 85 degrees C (40 to 185 degrees F)
-
Atmosphere: Important: Drive must not be installed in an area where the ambient atmosphere contains volatile or corrosive gas, vapors or dust. If the drive is not going to be installed for a period of time, it must be stored in an area where it will not be exposed to a corrosive atmosphere.
-
Relative Humidity: 0 to 95% non-condensing
-
Shock (operating): 15G peak for 11ms duration (.0ms)
-
Vibration (operating): 1G peak, 5 to 2000 Hz
-
Control Method Sine coded PWM with programmable carrier frequency. The drive is supplied as a 6 pulse converter.
-
Carrier Frequency 2-16 kHz. Drive rating based on 4 kHz.
-
Frequency Accuracy Digital Input: Within .05% of set output frequency.
-
Analog Input: Within 0.5% of maximum output frequency.
-
Speed Regulation - Open Loop
-
with Slip Compensation: % of base speed across a 40:1 speed range.
-
Stop Modes: Multiple programmable stop modes including - Ramp, Coast, DC-Brake, Ramp-to-Hold and S Curve.
-
Accel/Decel: Two independently programmable accel and decel times. Each time may be programmed from 0 - 600 seconds in 0.1 second increments.
-
Intermittent Overload: 150% Overload capability for up to 1 minute
-
200% Overload capability for up to 3 seconds
-
Electronic Motor Overload
-
Protection Class 10 protection with speed sensitive
-
response.