Zastosowanie:
  • równoległy pomiar dwóch temperatur oraz Delty T, ustalanie temperatury przegrzania oraz dalsze zadania w zależności od podłączonego urządzenia (np. z analizatorem HG3 określanie temperatury wyjściowej z parownika, a z termoparą ATC3 sprawdzian zablokowanych filtrów).

  • Parallel measurement of two temperatures and Delta T, temperature setting overheating and further tasks depending on the connected device (eg. the analyzer HG3 determining the starting temperature of the evaporator, and thermocouple test ATC3 blocked filters).
Opis produktu:
ATH4, jedna z głowic pomiarowych jakie można zastosować w miernikach Fieldpiece bądź innych, umożliwia równoległe zmierzenie dwóch temperatur. Od zastosowanego rodzaju termopary zależy co będzie przedmiotem pomiaru. W zestawie użytkownik otrzymuje dwie uniwersalne termopary typu K, ATB1. Jednak do głowicy można podłączyć również inne wersje:
  • ATA1 - termopara ATB1 z zaciskiem (z tzw. krokodylkiem),
  • ATAF1 - termopara ATA1 w wersji dla wysokich temperatur,
  • ATWB1 - termopara przeznaczona do pomiaru temperatury termometru mokrego,
  • ATF1 - termopara o długości 15 cm przeznaczona do płynów,
  • ATP1 - termopara przystosowana do przebijania ciał półstałych,
  • ATEXT10 - termopara na 3 m przedłużaczu,
  • ATC3 - termopara przeznaczona do rur.

Podłączone termopary podają Fieldpiece ATH4 odnotowane napięcie, które zostaje przełożone na temperaturę, wyrażaną jednak w wartościach mVDC (w relacji 0.1º na 0.1mVDC), przez miernik ustawiony na taki zakres. Wyświetlacz dołączonego miernika poda trzy wartości: obu termopar (T1 i T2) oraz Deltę T.

Tak jak inne głowice Fieldpiece, termometr z termoparami można podłączyć bezpośrednio do uniwersalnych mierników. W przypadku innych narzędzi, jak rejestrator DL3 czy analizator układu HG3, należy zastosować przewody pomiarowe ADLS2 lub złączkę uchwytu AHDL1. Termometr ATH4 będzie również współpracował z każdym cyfrowym multimetrem wyposażonym w standardowe gniazda, o impedancji wejściowej 9 lub 10 MOhm.

Zalety:
  • podawanie dwóch temperatur oraz różnicy między tymi wartościami w ºF lub ºC, regulowane prosto dwoma przełącznikami;
  • czujniki termopar (o kształcie drobnych kulek na zakończeniach przewodów) mogą mierzyć temperaturę powietrza lub powierzchni z którą mają kontakt;
  • zdolność przeliczania temperatur z zakresu -45 ºC - 980 ºC (do najwyższych temperatur wymagany dostępny opcjonalnie rodzaj termopar);
  • termopary izolowane do temperatur rzędu 200 ºC;
  • kształt termopar pozwala owijać wokół nich przewód z czujnikiem na czas przechowywania termometru;
  • wtykowe wejścia termopar umieszczone w niszy głowicy dla zapewnienia stabilnych warunków badania;
  • aby ułatwić pomiar temperatur rur, głowicę wyposażono w dwa paski rzepowe, przytrzymujące końcówki termopar przy rurze;
  • technologia zastosowana w głowicy świetnie zdaje egzamin w zakresie kompensacji wpływu gwałtownie zmieniającej się temperatury zewnętrznej, sytuacji częstej w codziennej pracy z urządzeniem;
  • w warunkach roboczych cały układ (termometr z termoparami połączony z miernikiem) można łatwo skalibrować za pomocą wody z lodem, z dokładnością do ±1ºC;
  • funkcja auto-off (możliwa do wyłączenia) oszczędza baterię urządzenia.


  • ATH4, one of the measuring heads that can be used in Fieldpiece gauges or other, allows parallel measuring two temperatures. Since the type of thermocouple used depends on what will be the subject of measurement. Includes user receives two universal thermocouple type K, ATB1. However, the head can also connect other versions:
    • ATA1 - ATB1 with clamp thermocouple (the so-called. Alligator clip)
    • ATAF1 - thermocouple ATA1 version for high temperatures < li> ATWB1 - thermocouple designed to measure wet bulb temperature
    • ATF1 - thermocouple with a length of 15 cm intended for liquids,
    • ATP1 - thermocouple adapted to pierce the bodies of semi-
    • ATEXT10 - thermocouple extension cable 3 m
    • ATC3 - designed for thermocouple tubes.

      Connected thermocouples give Fieldpiece ATH4 noted the tension that is translated into heat, but in the values ​​expressed mVDC (in relation to 0.1mVDC 0.1º), by the meter set to such a range. The display included with the meter will give three values: the two thermocouples (T1 and T2) and Delta T.

      Like other heads Fieldpiece, thermocouple thermometer can be connected directly to the universal metrics. For other tools, such as recorder and analyzer system DL3 HG3, use test leads or connector holder ADLS2 AHDL1. ATH4 thermometer will also collaborated with any digital multimeter equipped with a standard socket, input impedance 9 or 10 MW. Highlights:

      • The administration of the two temperatures and the difference between these values ​​in ° F or ° C, adjustable straight two switches;
      • sensors thermocouples (in the shape of small balls on the ends of the cables) can measure the temperature of the air or surfaces that have contact;
      • The ability of converting temperatures between -45 ° C - 980 ° C (the highest temperature required type thermocouples available as an option);
      • insulated thermocouple to a temperature of 200 ° C;
      • thermocouples shape allows them to wrap around the sensor cable for storage thermometer;
      • Plug-input thermocouple placed in the niche of the head to ensure stable test conditions;
      • to help measure the temperatures of pipes, the head is equipped with two strips of Velcro, holding the ends of thermocouples with pipe;
      • The technology used in the well head passes the test with regard to compensate for the rapidly changing external temperature, frequent situations in everyday work with the device;
      • the operating conditions of the circuit (thermometer with thermocouple connected with a meter) can be easily calibrated using ice water, with an accuracy of ± 1 ° C;
      • Auto-off function (possible to switch off) saves the battery of the device.
Specyfikacja:
  • Wejścia: dwie termopary typu K;
  • Wyjścia: przełączalne: T1, T2, T1-T2, standardowe wtyki bananowe;
  • Kalibracja: dwa zewnętrzne pokrętła regulacyjne;
  • Dokładność konwersji: 1mV DC na 1°;
  • Zakres: -46 do 982°C;
  • Rozdzielczość: 0,1° dla mierników z dokładnością 0,1mVDC;
  • Bateria: standardowa 9V;
  • Żywotność baterii: 200 godzin ciągłej pracy;
  • Automatyczne wyłączanie: po 15 minutach;
  • Kontrolki: zielona wskazuje że urządzenie jest włączone, czerwona niski poziom naładowania baterii;
  • Maksymalne napięcie wejściowe: 60 V DC, 24 V AC. Uwaga: silne pola częstotliwości radiowej mogą ujemnie wypływać na działanie konwertera.
  • Temperatura robocza: -34 do 49°C;
  • Temperatura przechowywania: -20 do 60°C;
  • Izolacja sondy: teflon, do 260°C;
  • Dokładność systemu przy 24°C ±3°C otoczenia, po kalibracji w stosunku do temperatury wody z lodem: ±0,5°C, -46 do 73°C; ±1°C, 74 do 176°C; ±2°C, 176 do 926°C.
  • Dokładność głowicy: ±0,5% + 2°C, -46 do 982°C.
  • Dokładność termopary: ±2°C lub ±0,75%, w zależności od tego, która z wartości jest większa, -34 do 815°C.

  • Inputs: two type K thermocouples;
  • Outputs: switchable: T1, T2, T1-T2 standard banana plugs;
  • Calibration: two external adjustment knobs;
  • Conversion Accuracy: 1 mV dc to 1 °;
  • Range: -46 to 982 ° C;
  • Resolution: 0,1 ° for the meter to the nearest 0,1mVDC;
  • Battery: Standard 9V;
  • Battery life: 200 hours of continuous operation;
  • Auto Power Off: After 15 minutes;
  • LEDs: green indicates that the device is switched on, the red low battery;
  • Maximum input voltage: 60 V DC, 24 V AC. Note: strong radiofrequency fields can be highly detrimental to the converter.
  • Operating temperature: -34 to 49 ° C;
  • Storage temperature: -20 to 60 ° C;
  • Isolation probe Teflon, to 260 ° C;
  • The accuracy of the system at 24 ° C ± 3 ° C, ambient, after calibration the temperature of ice-water: ± 0.5 ° C, -46 to 73 ° C; ± 1 ° C, 74 to 176 ° C; ± 2 ° C, 176 to 926 ° C.
  • The accuracy of the head: ± 0.5% ± 2 ° C, -46 to 982 ° C.
  • Thermocouple accuracy: ± 2 ° C or ± 0.75%, depending on which value is greater, -34 to 815 ° C.
Informacje dodatkowe:
W zestawie:
  • termometr ATH4,
  • dwie termopary ATB1,
  • dwa paski rzepowe,
  • miniśrubokręt do kalibracji,
  • bateria 9V (założona),
  • instrukcja obsługi.


  • Included:
    • thermometer ATH4
    • Two thermocouples ATB1
    • > two strips of Velcro,
    • miniśrubokręt for calibration,
    • 9V battery (installed),
    • manual.