Specification | |
---|---|
Conforming to Standards | EN1088, IEC60947-5-1, EN60947-5-1, ISO14119, GS-ET-19, UL508, CSA C22.2 No. 14, GB14048 (CCC approval), IEC60204-1, EN60204-1 (applicable standards for use) |
Operating Temperature | -20 to +40°C (no freezing) |
Storage Temperature | -40 to +80°C |
Relative Humidity | 40 - 85% RH (no condensation) |
Altitude | 2,000m maximum |
Rated Insulation Voltage (Ui) | 300V (between LED or solenoid and ground: 60V) |
Impulse Withstand Voltage (Uimp) | 4 kV (between LED or solenoid and ground: 2.5 kV) |
Insulation Resistance | Measured with 500V DC megger; Between live metal part and ground: 100 MΩ minimum; Between metal parts: 100 MΩ minimum; Between terminals of the same pole: 100 MΩ minimum |
Electric Shock Protection | Class II according to IEC61140 |
Pollution Degree | 3 (IEC60947-5-1) |
Degree of Protection | IP67 |
Vibration Operating Extremes Resistance | 10 to 55 Hz, minimum amplitude 0.35 mm |
Vibration Damage Limits Resistance | 147 m/sec² (approx. 15G) |
Shock Resistance | 1,000 m/sec² (approx. 100G) |
Actuator Retention Force | 1,500N minimum (per GS-ET-19) |
Actuator Operating Speed | 0.1 to 0.5 m/sec |
Direct Opening Travel | 7 mm min. |
Direct Opening Force | 15N minimum (latch type) |
Thermal Current (Ith) | 10A |
Contact Gap | 1.7 mm min., Auxiliary circuit: 1.2 mm min. |
Operating Frequency | 900 operations/hour max. |
Mechanical Life | 1,000,000 operations min. (at full rated load) |
Electrical Life | 100,000 operations (at rated load) |
Conditional Short-circuit Current | 100A (per IEC60947-5-1) |
Recommended Short Circuit Protection | Type D01 based on IEC60269-1, 60269-2 |
Operating Voltage | 24V DC |
Coil Resistance | 292Ω (initial value) |
Pickup Voltage | 20.4V maximum (at 20°C) |
Drop Out Voltage | 2.4V minimum (at 20°C) |
Allowable Voltage Range | 26.4V max (continuous) |
Insulation Class | Class F |
Indicator Operating Voltage | 24V DC |
Indicator Current | 10mA |
Indicator Light Source | LED lamp |
Indicator Lens Color | Red or Green |
Weight (approx.) | 500g |
Contact Ratings for Operating Voltage (Ue) AC12 | 30V, 125V, 250V |
Contact Ratings for Operating Voltage (Ue) AC15 | 250V |
Contact Ratings for Resistive load (AC1) | 10A |
Contact Ratings for Inductive load (AC3) | 6A |
Contact Ratings for Inductive load (AC15) | 3A |
Contact Ratings for DC13 | 30V, 250V |
Rated Operating Current (Ie) for Resistive load (AC1) | 10A |
Rated Operating Current (Ie) for Inductive load (AC3) | 6A |
Rated Operating Current (Ie) for Inductive load (AC15) | 3A |
Rated Operating Current (Ie) for DC13 | 30V, 250V |
Shipping Policy
Our go-to options for small to medium items are USPS Ground Advantage and USPS Priority Mail, known for their reliable tracking and peace of mind.
Smaller items might qualify for USPS First Class Mail. Contact us to discuss this option before purchasing.
Note: This method is less recommended due to the potential for delays.
Return Policy
We offer a 30-day return policy, no questions asked. If you choose to provide a reason for the return, it will assist us in improving and fix the issue.
Packaging
Our items are packaged according to their needs—some in ESD bags with pins secured in protective sponge, others in foam-enclosed boxes. For larger quantities, options include broken tubes for transistors or cartons. We welcome your suggestions for packaging preferences.