P940 series pressure switches are micro contact type, and these are suitable for corrosive fluids and high pressure measurements. Dead band is fixed.
Nominal diameter |
Refer to dimension drawing |
Repeatability |
±1.0 % of adjustable range |
Adjustable setting range (MPa, kPa, bar) |
-0.1 ~ 0 to -0.1 ~ 2.5 MPa
0 ~ 0.1 to 0 ~ 35 MPa |
Dead band |
Fixed
One SPDT : Approx. 5 % adjustable range
Two SPDT : Approx. 10 % of adjustable range |
Working temperature |
Ambient : -20 ~ 65 °C
Fluid : Max. 100 °C |